256 × 192 native thermal sensor,
NETDnot published by the manufacturer mK, 25 Hz.
Number of the sensor's measurement points, shown to the catalog's scale.
The largest sensor in the database has 327 680 points.
Published by the manufacturer
Specifications
Values come from manufacturer documentation unless otherwise
noted in the sources at the bottom of the page. This device has not been physically tested.
Identity
Brand
UNI-T
Model
UTi720M
Series
720
Commercial status
current
EAN code
not published by the manufacturer
Manufacturer reference
UTi720M
Segment
S1
Sensor and image
Native resolution, width (px)
256
Native resolution, height (px)
192
Native detector pixels
49152
Displayed resolution, width (px)
not applicable
Displayed resolution, height (px)
not applicable
Interpolation method
none
Detector type
uncooled microbolometer
Detector material
not published by the manufacturer
Pixel pitch (µm)
not published by the manufacturer
Spectral band, min (µm)
not published by the manufacturer
Spectral band, max (µm)
not published by the manufacturer
NETD (mK)
not published by the manufacturer
NETD measurement conditions
not published by the manufacturer
Frame rate (Hz)
25
Optics
Horizontal field of view (°)
not published by the manufacturer
Vertical field of view (°)
not published by the manufacturer
Advertised IFOV (mrad)
not published by the manufacturer
Minimum focus distance (m)
not published by the manufacturer
Focus
fixed
Interchangeable lenses
no
Digital zoom (×)
not published by the manufacturer
Measurement
Range min (°C)
-20
Range max (°C)
200
Absolute accuracy (°C)
not published by the manufacturer
Relative accuracy (%)
not published by the manufacturer
Emissivity setting
not published by the manufacturer
Reflected temperature correction
not published by the manufacturer
Measurement modes
not published by the manufacturer
Simultaneous cursors
9
Full radiometry
not published by the manufacturer
Visible channel
Visible camera (MP)
not applicable
Image fusion
no
LED light
no
Laser pointer
no
Ergonomics and ruggedness
Screen (inches)
not applicable
Screen resolution
not applicable
Touchscreen
not applicable
Weight (g)
not published by the manufacturer
Dimensions (mm)
not published by the manufacturer
IP rating
not published by the manufacturer
Drop resistance (m)
not published by the manufacturer
Power
Power type
host-powered
Battery system
not applicable
Battery life (h)
not applicable
Charging connector
not applicable
Storage and connectivity
Internal memory (GB)
not applicable
Memory card
not applicable
Wi-Fi
not applicable
Bluetooth
not applicable
Wired interface
USB-C
Software
Mobile app
UNI-T (Android)
Report generation
not published by the manufacturer
Cloud service
not published by the manufacturer
Compliance
Calibration certificate provided
not published by the manufacturer
Declared standards
not published by the manufacturer
Warranty (months)
not published by the manufacturer
Support in France
not published by the manufacturer
Observations
The narrowest measurement range of any smartphone module in this comparison. Capped at 200°C, versus 550 to 600°C for most direct competitors like the already-covered InfiRay P2 Pro or Thermal Master P2 Pro. A choice that limits the device to domestic use and low-voltage electrical inspection, ruling out any industrial or heating-related use.
Distribution restricted to the United States, Canada, and Puerto Rico at some distributors, a pattern already seen on several FLIR and Fluke devices in this comparison but rare for a Chinese manufacturer.
Neither NETD nor field of view are published in the sources consulted at this stage.