Compare fixed radiometric cameras by resolution, optics, ranges, interfaces and integration. A selection guide without an artificial ranking.
Compare documented systems
| Device | Native sensor | NETD | Optics | Range | Documented interface |
|---|---|---|---|---|---|
| Optris PI 640 | 640 × 480 | 75 mK | 33° | -20 / 900 °C | USB |
| Optris Xi 410 LT ETH | 384 × 240 | 60 mK | 29° | -20 / 1500 °C | Ethernet / USB 2.0 / PoE / RS-485 |
| Optris PI 400i LT | 382 × 288 | 75 mK | 29° | -20 / 1500 °C | USB 2.0; optional GigE/PoE server |
| FLIR A70 Smart Sensor Advanced | 640 × 480 | 35 mK | 51° | -20 / 1000 °C | Ethernet Gigabit / PoE / M12 / RS-232 |
| Optris Xi 640 LT USB (22°) | 640 × 480 | 80 mK | 22° | -20 / 900 °C | USB 2.0 |
| FLIR AX8 | 80 × 60 | 100 mK | 48° | -10 / 150 °C | Ethernet / Modbus TCP / EtherNet/IP / PoE |
Plan an installation
These devices continuously monitor an asset or process. They are not selected like handheld cameras. This is a documentary comparison, with no performance order or new score; it does not certify industrial integration.
- Specify measurable area and the lens at the real distance, not just pixel count.
- Verify standalone versus PC operation, software licences and SDK, protocols, alarms and network-failure behaviour.
- Budget for housing, cooling, air purge, cables, power, converters and integration.
- Isolate the camera network, control access and avoid Internet-exposed streams.
- A thermal camera alone does not replace a regulated fire-detection system.