Skip to content
The Thermogram

UNI-T · segment S2

UNI-T UTi120T

€€

120 × 90 native thermal sensor, NETD 60 mK, 25 Hz.

    10 800 points measured
    Number of the sensor's measurement points, shown to the catalog's scale. The largest sensor in the database has 327 680 points.
    Published by the manufacturer

    Two frame rates in the catalog. UNI-T lists this model in both 25 Hz and 9 Hz, like Fluke. A Chinese manufacturer not subject to export controls nonetheless offers a capped version, likely for its own export markets.

    Discrepancy to verify. The advertised IFOV is 7.6 mrad, while recalculating from the 50° field of view and 120 columns gives 7.27 mrad, a 4% discrepancy.

    Specifications

    Values come from manufacturer documentation unless otherwise noted in the sources at the bottom of the page. This device has not been physically tested.

    Identity
    BrandUNI-T
    ModelUTi120T
    SeriesPocket
    Release yearnot published by the manufacturer
    Commercial statuscurrent
    EAN codenot published by the manufacturer
    Manufacturer referenceUTi120T
    SegmentS2
    Sensor and image
    Native resolution, width (px)120
    Native resolution, height (px)90
    Native detector pixels10800
    Displayed resolution, width (px)not applicable
    Displayed resolution, height (px)not applicable
    Interpolation methodnone
    Detector typeuncooled microbolometer
    Detector materialnot published by the manufacturer
    Pixel pitch (µm)not published by the manufacturer
    Spectral band, min (µm)not published by the manufacturer
    Spectral band, max (µm)not published by the manufacturer
    NETD (mK)60
    NETD measurement conditionsnot published by the manufacturer
    Frame rate (Hz)25
    Optics
    Horizontal field of view (°)50
    Vertical field of view (°)38
    Advertised IFOV (mrad)7.6
    Recalculated IFOV (mrad)7.27
    Minimum focus distance (m)not published by the manufacturer
    Focusfixed
    Interchangeable lensesno
    Digital zoom (×)not published by the manufacturer
    Macro lens
    Availabilityno
    Referencenot applicable
    Working distance (mm)not applicable
    Spot size (µm)not applicable
    Smallest measurable area (µm)not applicable
    Accuracy with macro (°C)not applicable
    Range max with macro (°C)not applicable
    Measurement
    Range min (°C)-20
    Range max (°C)400
    Absolute accuracy (°C)2
    Relative accuracy (%)2
    Emissivity settingnot published by the manufacturer
    Reflected temperature correctionnot published by the manufacturer
    Measurement modes1
    Simultaneous cursorsnot published by the manufacturer
    Full radiometrynot published by the manufacturer
    Visible channel
    Visible camera (MP)not published by the manufacturer
    Image fusionnot published by the manufacturer
    LED lightnot published by the manufacturer
    Laser pointernot published by the manufacturer
    Ergonomics and ruggedness
    Screen (inches)not published by the manufacturer
    Screen resolutionnot published by the manufacturer
    Touchscreennot published by the manufacturer
    Weight (g)not published by the manufacturer
    Dimensions (mm)not published by the manufacturer
    IP ratingnot published by the manufacturer
    Drop resistance (m)not published by the manufacturer
    Operating temperature, min (°C)not published by the manufacturer
    Operating temperature, max (°C)not published by the manufacturer
    Power
    Power typebuilt-in battery
    Battery systemnot applicable
    Battery life (h)not published by the manufacturer
    Charging connectornot published by the manufacturer
    Storage and connectivity
    Internal memory (GB)not published by the manufacturer
    Memory cardnot published by the manufacturer
    Wi-Finot published by the manufacturer
    Bluetoothnot published by the manufacturer
    Wired interfacenot published by the manufacturer
    File formatsnot published by the manufacturer
    Software
    PC softwarenot published by the manufacturer
    Free PC softwarenot published by the manufacturer
    Mobile appnot published by the manufacturer
    Report generationnot published by the manufacturer
    Cloud servicenot published by the manufacturer
    Compliance
    Calibration certificate providednot published by the manufacturer
    Declared standardsnot published by the manufacturer
    Warranty (months)not published by the manufacturer
    Support in Francenot published by the manufacturer

    Observations

    • No ergonomics, ruggedness, or connectivity data published.