UNI-T UTi120S

€€

120 × 90 native thermal sensor, NETD not published by the manufacturer mK, 25 Hz.

    10 800 points measured
    Number of the sensor's measurement points, shown to the catalog's scale. The largest sensor in the database has 327 680 points.
    Published by the manufacturer

    Record battery life. At least 9 hours advertised, the best in the comparison, ahead of the HIKMICRO E1L's and Eco's 8 hours.

    Specifications

    Values come from manufacturer documentation unless otherwise noted in the sources at the bottom of the page. This device has not been physically tested.

    Identity
    BrandUNI-T
    ModelUTi120S
    SeriesPocket
    Release yearnot published by the manufacturer
    Commercial statuscurrent
    EAN codenot published by the manufacturer
    Manufacturer referenceUTi120S
    SegmentS2
    Sensor and image
    Native resolution, width (px)120
    Native resolution, height (px)90
    Native detector pixels10800
    Displayed resolution, width (px)not applicable
    Displayed resolution, height (px)not applicable
    Interpolation methodnone
    Detector typeuncooled microbolometer
    Detector materialnot published by the manufacturer
    Pixel pitch (µm)17
    Spectral band, min (µm)not published by the manufacturer
    Spectral band, max (µm)not published by the manufacturer
    NETD (mK)not published by the manufacturer
    NETD measurement conditionsnot published by the manufacturer
    Frame rate (Hz)25
    Optics
    Horizontal field of view (°)not published by the manufacturer
    Vertical field of view (°)not published by the manufacturer
    Advertised IFOV (mrad)not published by the manufacturer
    Minimum focus distance (m)not published by the manufacturer
    Focusfixed
    Interchangeable lensesno
    Digital zoom (×)not published by the manufacturer
    Macro lens
    Availabilityno
    Referencenot applicable
    Working distance (mm)not applicable
    Spot size (µm)not applicable
    Smallest measurable area (µm)not applicable
    Accuracy with macro (°C)not applicable
    Range max with macro (°C)not applicable
    Measurement
    Range min (°C)-20
    Range max (°C)400
    Absolute accuracy (°C)not published by the manufacturer
    Relative accuracy (%)not published by the manufacturer
    Emissivity settingcontinuous
    Reflected temperature correctionnot published by the manufacturer
    Measurement modes1
    Simultaneous cursorsnot published by the manufacturer
    Full radiometrynot published by the manufacturer
    Visible channel
    Visible camera (MP)not published by the manufacturer
    Image fusionnot published by the manufacturer
    LED lightyes
    Laser pointeryes
    Ergonomics and ruggedness
    Screen (inches)not published by the manufacturer
    Screen resolution320 × 240
    Touchscreenno
    Weight (g)310
    Dimensions (mm)197 × 72 × 60
    IP ratingIP54
    Drop resistance (m)2
    Operating temperature, min (°C)not published by the manufacturer
    Operating temperature, max (°C)not published by the manufacturer
    Power
    Power typebuilt-in battery
    Battery systemnot applicable
    Battery life (h)9
    Charging connectorUSB-C
    Storage and connectivity
    Internal memory (GB)not applicable
    Memory cardmicroSD
    Wi-Finot published by the manufacturer
    Bluetoothnot published by the manufacturer
    Wired interfaceUSB-C
    File formatsnot published by the manufacturer
    Software
    PC softwareUNI-T (analyse PC)
    Free PC softwarenot published by the manufacturer
    Mobile appnot published by the manufacturer
    Report generationnot published by the manufacturer
    Cloud servicenot published by the manufacturer
    Compliance
    Calibration certificate providednot published by the manufacturer
    Declared standardsnot published by the manufacturer
    Warranty (months)not published by the manufacturer
    Support in Francenot published by the manufacturer

    Observations

    • A 17 µm pixel pitch, an older detector generation than the 12 µm of more recent models.
    • UNI-T DOES NOT PUBLISH THIS MODEL'S NETD, nor its field of view, nor its measurement accuracy — the three specs that determine what the device can actually do.
    • High and low alarms via image, sound, and LED, six palettes, tripod thread.