Skip to content
The Thermogram

TOPDON · segment S1

TOPDON TC002C Duo

€€

256 × 192 native thermal sensor, NETD 40 mK, 25 Hz.

    49 152 points measured · 196 608 displayed
    Number of the sensor's measurement points, shown to the catalog's scale. The largest sensor in the database has 327 680 points.
    Published by the manufacturer

    Discrepancy to flag. TOPDON advertises a field of view of 50° × 37.2° on all its product pages, while Notebookcheck's independent review measured 56° × 42°, the same value as the TC001 Max and the InfiRay P2 Pro. Value used here: the manufacturer's, but the discrepancy warrants verification.

    Specifications

    Values come from manufacturer documentation unless otherwise noted in the sources at the bottom of the page. This device has not been physically tested.

    Identity
    BrandTOPDON
    ModelTC002C Duo
    SeriesTCView
    Release year2025
    Commercial statuscurrent
    EAN codenot published by the manufacturer
    Manufacturer referencenot published by the manufacturer
    SegmentS1
    Sensor and image
    Native resolution, width (px)256
    Native resolution, height (px)192
    Native detector pixels49152
    Displayed resolution, width (px)512
    Displayed resolution, height (px)384
    Interpolation ratio4.0
    Interpolation methodsoftware
    Detector typeuncooled microbolometer
    Detector materialnot published by the manufacturer
    Pixel pitch (µm)not published by the manufacturer
    Spectral band, min (µm)not published by the manufacturer
    Spectral band, max (µm)not published by the manufacturer
    NETD (mK)40
    NETD measurement conditions< 40 mK (measurement conditions not specified)
    Frame rate (Hz)25
    Optics
    Horizontal field of view (°)50
    Vertical field of view (°)37.2
    Advertised IFOV (mrad)not published by the manufacturer
    Recalculated IFOV (mrad)3.41
    Minimum focus distance (m)not published by the manufacturer
    Focusfixed
    Interchangeable lensesno
    Digital zoom (×)not published by the manufacturer
    Macro lens
    Availabilityno
    Referencenot applicable
    Working distance (mm)not applicable
    Spot size (µm)not applicable
    Smallest measurable area (µm)not applicable
    Accuracy with macro (°C)not applicable
    Range max with macro (°C)not applicable
    Measurement
    Range min (°C)-20
    Range max (°C)550
    Absolute accuracy (°C)2
    Relative accuracy (%)2
    Emissivity settingnot published by the manufacturer
    Reflected temperature correctionnot published by the manufacturer
    Measurement modes3
    Simultaneous cursorsnot published by the manufacturer
    Full radiometrynot published by the manufacturer
    Visible channel
    Visible camera (MP)not applicable
    Image fusionno
    LED lightno
    Laser pointerno
    Ergonomics and ruggedness
    Screen (inches)not applicable
    Screen resolutionnot applicable
    Touchscreennot applicable
    Weight (g)30
    Dimensions (mm)71 × 42 × 14
    IP ratingnot published by the manufacturer
    Drop resistance (m)not published by the manufacturer
    Operating temperature, min (°C)not published by the manufacturer
    Operating temperature, max (°C)not published by the manufacturer
    Power
    Power typehost-powered
    Battery systemnot applicable
    Battery life (h)not applicable
    Charging connectornot applicable
    Storage and connectivity
    Internal memory (GB)not applicable
    Memory cardnot applicable
    Wi-Finot applicable
    Bluetoothnot applicable
    Wired interfaceUSB-C
    File formatsnot published by the manufacturer
    Software
    PC softwareTopView (Windows)
    Free PC softwareyes
    Mobile appTopInfrared (iOS et Android)
    Report generationyes
    Cloud servicenot published by the manufacturer
    Compliance
    Calibration certificate providednot published by the manufacturer
    Declared standardsnot published by the manufacturer
    Warranty (months)not published by the manufacturer
    Support in Francenot published by the manufacturer

    Observations

    • TISR brings the display from 256×192 up to 512×384, a ratio of 4: three out of every four pixels are reconstructed.
    • The same 71 × 42 × 14 mm housing as the TC001, likely the same sensor.
    • An advertised accuracy of ±1°C under 150°C according to Notebookcheck, ±2°C above.

    Sources