Number of the sensor's measurement points, shown to the catalog's scale.
The largest sensor in the database has 327 680 points.
Published by the manufacturer
Discrepancy to flag. TOPDON advertises a field of view of 50° × 37.2° on all its product pages, while Notebookcheck's independent review measured 56° × 42°, the same value as the TC001 Max and the InfiRay P2 Pro. Value used here: the manufacturer's, but the discrepancy warrants verification.
Specifications
Values come from manufacturer documentation unless otherwise
noted in the sources at the bottom of the page. This device has not been physically tested.
Identity
Brand
TOPDON
Model
TC002C Duo
Series
TCView
Release year
2025
Commercial status
current
EAN code
not published by the manufacturer
Manufacturer reference
not published by the manufacturer
Segment
S1
Sensor and image
Native resolution, width (px)
256
Native resolution, height (px)
192
Native detector pixels
49152
Displayed resolution, width (px)
512
Displayed resolution, height (px)
384
Interpolation ratio
4.0
Interpolation method
software
Detector type
uncooled microbolometer
Detector material
not published by the manufacturer
Pixel pitch (µm)
not published by the manufacturer
Spectral band, min (µm)
not published by the manufacturer
Spectral band, max (µm)
not published by the manufacturer
NETD (mK)
40
NETD measurement conditions
< 40 mK (measurement conditions not specified)
Frame rate (Hz)
25
Optics
Horizontal field of view (°)
50
Vertical field of view (°)
37.2
Advertised IFOV (mrad)
not published by the manufacturer
Recalculated IFOV (mrad)
3.41
Minimum focus distance (m)
not published by the manufacturer
Focus
fixed
Interchangeable lenses
no
Digital zoom (×)
not published by the manufacturer
Macro lens
Availability
no
Reference
not applicable
Working distance (mm)
not applicable
Spot size (µm)
not applicable
Smallest measurable area (µm)
not applicable
Accuracy with macro (°C)
not applicable
Range max with macro (°C)
not applicable
Measurement
Range min (°C)
-20
Range max (°C)
550
Absolute accuracy (°C)
2
Relative accuracy (%)
2
Emissivity setting
not published by the manufacturer
Reflected temperature correction
not published by the manufacturer
Measurement modes
3
Simultaneous cursors
not published by the manufacturer
Full radiometry
not published by the manufacturer
Visible channel
Visible camera (MP)
not applicable
Image fusion
no
LED light
no
Laser pointer
no
Ergonomics and ruggedness
Screen (inches)
not applicable
Screen resolution
not applicable
Touchscreen
not applicable
Weight (g)
30
Dimensions (mm)
71 × 42 × 14
IP rating
not published by the manufacturer
Drop resistance (m)
not published by the manufacturer
Operating temperature, min (°C)
not published by the manufacturer
Operating temperature, max (°C)
not published by the manufacturer
Power
Power type
host-powered
Battery system
not applicable
Battery life (h)
not applicable
Charging connector
not applicable
Storage and connectivity
Internal memory (GB)
not applicable
Memory card
not applicable
Wi-Fi
not applicable
Bluetooth
not applicable
Wired interface
USB-C
File formats
not published by the manufacturer
Software
PC software
TopView (Windows)
Free PC software
yes
Mobile app
TopInfrared (iOS et Android)
Report generation
yes
Cloud service
not published by the manufacturer
Compliance
Calibration certificate provided
not published by the manufacturer
Declared standards
not published by the manufacturer
Warranty (months)
not published by the manufacturer
Support in France
not published by the manufacturer
Observations
TISR brings the display from 256×192 up to 512×384, a ratio of 4: three out of every four pixels are reconstructed.
The same 71 × 42 × 14 mm housing as the TC001, likely the same sensor.
An advertised accuracy of ±1°C under 150°C according to Notebookcheck, ±2°C above.