256 × 192 native thermal sensor, NETD 40 mK, 25 Hz.

    49 152 points measured · 196 608 displayed
    Number of the sensor's measurement points, shown to the catalog's scale. The largest sensor in the database has 327 680 points.
    Published by the manufacturer

    Specifications

    Values come from manufacturer documentation unless otherwise noted in the sources at the bottom of the page. This device has not been physically tested.

    Identity
    BrandThermal Master
    ModelP2
    SeriesP
    Release year2023
    Commercial statuscurrent
    EAN codenot published by the manufacturer
    Manufacturer referencenot published by the manufacturer
    SegmentS1
    Sensor and image
    Native resolution, width (px)256
    Native resolution, height (px)192
    Native detector pixels49152
    Displayed resolution, width (px)512
    Displayed resolution, height (px)384
    Interpolation ratio4.0
    Interpolation methodsoftware
    Detector typeuncooled microbolometer
    Detector materialnot published by the manufacturer
    Pixel pitch (µm)not published by the manufacturer
    Spectral band, min (µm)not published by the manufacturer
    Spectral band, max (µm)not published by the manufacturer
    NETD (mK)40
    NETD measurement conditionsnot published by the manufacturer
    Frame rate (Hz)25
    Optics
    Horizontal field of view (°)56
    Vertical field of view (°)42.2
    Advertised IFOV (mrad)not published by the manufacturer
    Recalculated IFOV (mrad)3.82
    Minimum focus distance (m)not published by the manufacturer
    Focusfixed
    Interchangeable lensesno
    Digital zoom (×)not published by the manufacturer
    Measurement
    Range min (°C)-20
    Range max (°C)600
    Absolute accuracy (°C)1.5
    Relative accuracy (%)not published by the manufacturer
    Emissivity settingnot published by the manufacturer
    Reflected temperature correctionnot published by the manufacturer
    Measurement modes3
    Simultaneous cursorsnot published by the manufacturer
    Full radiometrynot published by the manufacturer
    Visible channel
    Visible camera (MP)not applicable
    Image fusionno
    LED lightno
    Laser pointerno
    Ergonomics and ruggedness
    Screen (inches)not applicable
    Screen resolutionnot applicable
    Touchscreennot applicable
    Weight (g)9.7
    Dimensions (mm)27 × 18 × 9,8
    IP ratingnot published by the manufacturer
    Drop resistance (m)not published by the manufacturer
    Power
    Power typehost-powered
    Battery systemnot applicable
    Battery life (h)not applicable
    Charging connectornot applicable
    Storage and connectivity
    Internal memory (GB)not applicable
    Memory cardnot applicable
    Wi-Finot applicable
    Bluetoothnot applicable
    Wired interfaceUSB-C
    Software
    Mobile appThermal Master (Android uniquement)
    Report generationnot published by the manufacturer
    Cloud servicenot published by the manufacturer
    Compliance
    Calibration certificate providednot published by the manufacturer
    Declared standardsnot published by the manufacturer
    Warranty (months)not published by the manufacturer
    Support in Francenot published by the manufacturer

    Observations

    • A VERSION WITHOUT THE MACRO LENS OF THE ALREADY-COVERED P2 PRO in this comparison: same 256 × 192 sensor, same 40 mK NETD, same dimensions and weight to the tenth, but no close-up accessory and Android only versus iOS and Android for the Pro. Comparing the two datasheets shows concretely how the sole difference between an entry-level module and its 'Pro' version can come down to a single bundled accessory.
    • SuperIR/Razor X brings the display up to 512 × 384, a ratio of 4, identical to the P2 Pro.
    • AN ADVERTISED ACCURACY OF ±1.5°C, better than the pricier P2 Pro, a discrepancy no retailer listing documents comparatively.

    Sources