Skip to content
The Thermogram

Seek Thermal · segment S1

Seek Thermal Nano 300

€€€

320 × 240 genuinely measured detector, 35 mK NETD, 25 Hz.

    76,800 measured points
    Editorial detector visualization; the stated native-resolution figure is authoritative.
    Published by the manufacturer

    Specifications

    Values come from manufacturer documentation. This device has not been physically tested.

    Identity
    BrandSeek Thermal
    ModelNano 300
    SeriesNano
    Release year2024
    Commercial statuscurrent
    GTIN / EANnot published by the manufacturer
    Manufacturer part numbernot published by the manufacturer
    SegmentS1
    Sensor and image
    Native resolution, width (px)320
    Native resolution, height (px)240
    Native detector pixels76800
    Output resolution, width (px)not applicable
    Output resolution, height (px)not applicable
    Upscaling methodnone
    Detector typeuncooled microbolometer
    Detector materialVOx
    Pixel pitch (µm)12
    Spectral range, minimum (µm)7.8
    Spectral range, maximum (µm)14
    NETD (mK)35
    NETD measurement conditions35 mK at 25°C with SV1 optimization
    Frame rate (Hz)25
    Optics
    Horizontal field of view (°)57
    Vertical field of view (°)42
    Published IFOV (mrad)not published by the manufacturer
    Recalculated IFOV (mrad)3.11
    Minimum focus distance (m)not published by the manufacturer
    Focusfixed
    Interchangeable lensesno
    Digital zoom (×)not published by the manufacturer
    Macro capability
    Availabilityoptional
    ReferenceNano macro lens
    Working distance (mm)not published by the manufacturer
    Spot size (µm)not published by the manufacturer
    Smallest measurable area (µm)not published by the manufacturer
    Macro accuracy (°C)not published by the manufacturer
    Maximum macro range (°C)not published by the manufacturer
    Measurement
    Minimum range (°C)-20
    Maximum range (°C)330
    Absolute accuracy (°C)5
    Relative accuracy (%)5
    Emissivity controlnot published by the manufacturer
    Reflected-temperature correctionnot published by the manufacturer
    Measurement modesnot published by the manufacturer
    Simultaneous cursors3
    Full radiometryyes
    Visible channel
    Visible camera (MP)not applicable
    Image fusionno
    LED lightno
    Laser pointer or rangefinderno
    Ergonomics and ruggedness
    Display (inches)not applicable
    Display resolutionnot applicable
    Touchscreennot applicable
    Weight (g)13
    Dimensions (mm)25 × 25 × 22
    IP ratingnot published by the manufacturer
    Drop resistance (m)not published by the manufacturer
    Minimum operating temperature (°C)not published by the manufacturer
    Maximum operating temperature (°C)not published by the manufacturer
    Power
    Power typeexternal power
    Battery systemnot applicable
    Runtime (h)not applicable
    Charging connectornot applicable
    Storage and connectivity
    Internal memory (GB)not applicable
    Memory cardnot applicable
    Wi-Finot applicable
    Bluetoothnot applicable
    Wired interfaceUSB-C ou Lightning selon version
    File formatsradiometric photos and video
    Software
    Desktop softwarenot published by the manufacturer
    Free desktop softwarenot published by the manufacturer
    Mobile appSeek Nano (iOS et Android)
    Report generationnot published by the manufacturer
    Cloud servicenot published by the manufacturer
    Compliance
    Calibration certificate suppliednot published by the manufacturer
    Declared standardsnot published by the manufacturer
    Warranty (months)not published by the manufacturer
    Local service supportnot published by the manufacturer

    Notes

    • 320 × 240 NATIVE RESOLUTION, KEPT SEPARATE FROM SOFTWARE ENHANCEMENT: Seek confirms that all 76,800 points come from the detector.
    • The $519 public price shown on the official page provisionally places the model in the €€€ band; this indicative band never affects technical scoring.
    • An optional macro lens supports close inspections, but Seek does not publish a measurable spot size, so that field remains undocumented.

    Sources