Skip to content
The Thermogram

Hti · segment S2

Hti HT-18+

€€

256 × 192 native thermal sensor, NETD 50 mK, 25 Hz.

    49 152 points measured · 307 200 displayed
    Number of the sensor's measurement points, shown to the catalog's scale. The largest sensor in the database has 327 680 points.
    Published by the manufacturer

    Among the shortest battery life in the comparison. An advertised 2 to 3 hours, versus 7 to 9 hours for most standalone devices in the same price range already covered (HIKMICRO E1L, Eco, UNI-T UTi720A).

    Specifications

    Values come from manufacturer documentation unless otherwise noted in the sources at the bottom of the page. This device has not been physically tested.

    Identity
    BrandHti
    ModelHT-18+
    SeriesHT
    Commercial statuscurrent
    EAN codenot published by the manufacturer
    Manufacturer referencenot published by the manufacturer
    SegmentS2
    Sensor and image
    Native resolution, width (px)256
    Native resolution, height (px)192
    Native detector pixels49152
    Displayed resolution, width (px)640
    Displayed resolution, height (px)480
    Interpolation ratio6.25
    Interpolation methodsoftware
    Detector typeuncooled microbolometer
    Detector materialnot published by the manufacturer
    Pixel pitch (µm)12
    Spectral band, min (µm)8
    Spectral band, max (µm)14
    NETD (mK)50
    NETD measurement conditions≤ 50 mK @ 25 °C, F#=1.1
    Frame rate (Hz)25
    Optics
    Horizontal field of view (°)56
    Vertical field of view (°)42
    Advertised IFOV (mrad)3.75
    Recalculated IFOV (mrad)3.82
    Minimum focus distance (m)not published by the manufacturer
    Focusfixed
    Interchangeable lensesno
    Digital zoom (×)not published by the manufacturer
    Macro lens
    Availabilityno
    Referencenot applicable
    Working distance (mm)not applicable
    Spot size (µm)not applicable
    Smallest measurable area (µm)not applicable
    Accuracy with macro (°C)not applicable
    Range max with macro (°C)not applicable
    Measurement
    Range min (°C)-20
    Range max (°C)550
    Absolute accuracy (°C)2
    Relative accuracy (%)2
    Emissivity settingcontinuous
    Reflected temperature correctionnot published by the manufacturer
    Measurement modesnot published by the manufacturer
    Simultaneous cursorsnot published by the manufacturer
    Full radiometrynot published by the manufacturer
    Visible channel
    Visible camera (MP)not published by the manufacturer
    Image fusionnot published by the manufacturer
    LED lightnot published by the manufacturer
    Laser pointernot published by the manufacturer
    Ergonomics and ruggedness
    Screen (inches)3.2
    Screen resolution320 × 240
    Touchscreenno
    Weight (g)not published by the manufacturer
    Dimensions (mm)not published by the manufacturer
    IP ratingnot published by the manufacturer
    Drop resistance (m)not published by the manufacturer
    Operating temperature, min (°C)not published by the manufacturer
    Operating temperature, max (°C)not published by the manufacturer
    Power
    Power typebuilt-in battery
    Battery systemLithium 2200 mAh replaceable
    Battery life (h)2.5
    Charging connectormicro-USB
    Storage and connectivity
    Internal memory (GB)4
    Memory cardno
    Wi-Finot published by the manufacturer
    Bluetoothnot published by the manufacturer
    Wired interfacemicro-USB
    File formatsJPG and MP4 video
    Software
    PC softwarenot published by the manufacturer
    Free PC softwarenot published by the manufacturer
    Mobile appnot applicable
    Report generationnot published by the manufacturer
    Cloud servicenot published by the manufacturer
    Compliance
    Calibration certificate providednot published by the manufacturer
    Declared standardsnot published by the manufacturer
    Warranty (months)not published by the manufacturer
    Support in Francenot published by the manufacturer

    Observations

    • THE SAME F/1.1 APERTURE, BUT THIS TIME THE NETD IS SPECIFIED AT F#=1.1 — a consistency worth noting by contrast with the already-covered HIKMICRO Pocket2 and InfiRay P2 Pro in this comparison, where the lens's real aperture doesn't match the advertised NETD conditions. Here, at least on paper, the two values line up.
    • Part of the same range as the already-covered HT-A1 in this comparison, whose own notes already flagged a recurring mix-up between the thermal sensor's resolution and the visible camera's resolution for this brand; this particular model could be verified as consistent on that point.

    Sources