Number of the sensor's measurement points, shown to the catalog's scale.
The largest sensor in the database has 327 680 points.
Published by the manufacturer
Specifications
Values come from manufacturer documentation unless otherwise
noted in the sources at the bottom of the page. This device has not been physically tested.
Identity
Brand
HIKMICRO
Model
SP40H
Series
SP
Release year
not published by the manufacturer
Commercial status
current
EAN code
not published by the manufacturer
Manufacturer reference
not published by the manufacturer
Segment
S5
Sensor and image
Native resolution, width (px)
480
Native resolution, height (px)
360
Native detector pixels
172800
Displayed resolution, width (px)
960
Displayed resolution, height (px)
720
Interpolation ratio
4.0
Interpolation method
software
Detector type
uncooled microbolometer
Detector material
not published by the manufacturer
Pixel pitch (µm)
not published by the manufacturer
Spectral band, min (µm)
7.5
Spectral band, max (µm)
14
NETD (mK)
30
NETD measurement conditions
< 30 mK @ 25 °C, F#=1.0
Frame rate (Hz)
30
Optics
Horizontal field of view (°)
not published by the manufacturer
Vertical field of view (°)
not published by the manufacturer
Advertised IFOV (mrad)
not published by the manufacturer
Minimum focus distance (m)
not published by the manufacturer
Focus
automatic
Interchangeable lenses
yes
Digital zoom (×)
12
Macro lens
Availability
no
Reference
not applicable
Working distance (mm)
not applicable
Spot size (µm)
not applicable
Smallest measurable area (µm)
not applicable
Accuracy with macro (°C)
not applicable
Range max with macro (°C)
not applicable
Measurement
Range min (°C)
-40
Range max (°C)
2200
Absolute accuracy (°C)
1
Relative accuracy (%)
1
Emissivity setting
not published by the manufacturer
Reflected temperature correction
not published by the manufacturer
Measurement modes
not published by the manufacturer
Simultaneous cursors
not published by the manufacturer
Full radiometry
not published by the manufacturer
Visible channel
Visible camera (MP)
8
Image fusion
overlay
LED light
not published by the manufacturer
Laser pointer
yes
Ergonomics and ruggedness
Screen (inches)
not published by the manufacturer
Screen resolution
not published by the manufacturer
Touchscreen
yes
Weight (g)
not published by the manufacturer
Dimensions (mm)
not published by the manufacturer
IP rating
not published by the manufacturer
Drop resistance (m)
not published by the manufacturer
Operating temperature, min (°C)
not published by the manufacturer
Operating temperature, max (°C)
not published by the manufacturer
Power
Power type
built-in battery
Battery system
not applicable
Battery life (h)
4
Charging connector
not published by the manufacturer
Storage and connectivity
Internal memory (GB)
not applicable
Memory card
not published by the manufacturer
Wi-Fi
yes
Bluetooth
not published by the manufacturer
Wired interface
not published by the manufacturer
File formats
not published by the manufacturer
Software
PC software
HIKMICRO Analyzer
Free PC software
yes
Mobile app
HIKMICRO Viewer
Report generation
yes
Cloud service
not published by the manufacturer
Compliance
Calibration certificate provided
not published by the manufacturer
Declared standards
not published by the manufacturer
Warranty (months)
not published by the manufacturer
Support in France
not published by the manufacturer
Observations
A MEASUREMENT RANGE UP TO 2200°C, THE HIGHEST IN THE ENTIRE COMPARISON, ahead of the FLIR E96's optional 1500°C and the FLIR TG297's 1030°C. Positioned for foundries, industrial furnaces, and steelmaking — an even more extreme use case than the already-covered TG297 in this catalog.
An advertised accuracy of ±1°C between 0 and 100°C, better than almost every professional device in this comparison, which mostly sit around ±2°C.
Part of the same mechanical family as the already-documented SP60, with several interchangeable lenses depending on the exact model ordered.
Incomplete documentation on field of view, weight, and dimensions in the sources consulted, the high-temperature variant of the SP range being less publicly documented than the standard version.