Number of the sensor's measurement points, shown to the catalog's scale.
The largest sensor in the database has 327 680 points.
Published by the manufacturer
The best battery life in the comparison. An advertised 16 hours, nearly double the UNI-T UTi120S's 9 hours and four times a FLIR C5's 4 hours. Full charge in 2h30.
Geometric discrepancy to flag. The advertised field of view is 56° × 48°, a ratio of 1.17, while the 256 × 192 sensor has a ratio of 1.33. The two values are incompatible. The advertised IFOV of 3.75 mrad matches the horizontal field, not the vertical one.
Specifications
Values come from manufacturer documentation unless otherwise
noted in the sources at the bottom of the page. This device has not been physically tested.
Identity
Brand
Guide
Model
PC210
Series
PC
Release year
not published by the manufacturer
Commercial status
end of life
EAN code
not published by the manufacturer
Manufacturer reference
PC210
Segment
S2
Sensor and image
Native resolution, width (px)
256
Native resolution, height (px)
192
Native detector pixels
49152
Displayed resolution, width (px)
not applicable
Displayed resolution, height (px)
not applicable
Interpolation method
none
Detector type
uncooled microbolometer
Detector material
VOx
Pixel pitch (µm)
12
Spectral band, min (µm)
7.5
Spectral band, max (µm)
14
NETD (mK)
45
NETD measurement conditions
not published by the manufacturer
Frame rate (Hz)
25
Optics
Horizontal field of view (°)
56
Vertical field of view (°)
48
Advertised IFOV (mrad)
3.75
Recalculated IFOV (mrad)
3.82
Minimum focus distance (m)
0.3
Focus
fixed
Interchangeable lenses
no
Digital zoom (×)
not published by the manufacturer
Macro lens
Availability
no
Reference
not applicable
Working distance (mm)
not applicable
Spot size (µm)
not applicable
Smallest measurable area (µm)
not applicable
Accuracy with macro (°C)
not applicable
Range max with macro (°C)
not applicable
Measurement
Range min (°C)
-20
Range max (°C)
550
Absolute accuracy (°C)
2
Relative accuracy (%)
2
Emissivity setting
continuous
Reflected temperature correction
yes
Measurement modes
2
Simultaneous cursors
4
Full radiometry
not published by the manufacturer
Visible channel
Visible camera (MP)
2
Image fusion
overlay
LED light
yes
Laser pointer
yes
Ergonomics and ruggedness
Screen (inches)
2.4
Screen resolution
320 × 240
Touchscreen
no
Weight (g)
375
Dimensions (mm)
194 × 62 × 76
IP rating
IP54
Drop resistance (m)
2
Operating temperature, min (°C)
-10
Operating temperature, max (°C)
50
Power
Power type
built-in battery
Battery system
not applicable
Battery life (h)
16
Charging connector
USB-C
Storage and connectivity
Internal memory (GB)
not applicable
Memory card
microSD
Wi-Fi
not published by the manufacturer
Bluetooth
not published by the manufacturer
Wired interface
USB-C
File formats
not published by the manufacturer
Software
PC software
Guide Thermotools
Free PC software
not published by the manufacturer
Mobile app
not published by the manufacturer
Report generation
not published by the manufacturer
Cloud service
not published by the manufacturer
Compliance
Calibration certificate provided
not published by the manufacturer
Declared standards
not published by the manufacturer
Warranty (months)
12
Support in France
not published by the manufacturer
Observations
A NETD of 45 mK for a device sold around €340 excl. tax: better than the FLIR Ex Pro, the Bosch GTC, and the testo 860 series, all noticeably pricier.
A very wide 56° field of view, suited to scanning interior walls but poorly suited to circuit-board work.
SharpIR is presented as a composite image processing technique, not as a resolution boost: the advertised resolution is the native resolution.
Discontinued model, replaced by the Guide E2, but still widely available.