Number of the sensor's measurement points, shown to the catalog's scale.
The largest sensor in the database has 327 680 points.
Published by the manufacturer
Naming anomaly to flag. The device's commercial name is 'TiS60+ 30 Hz' at several distributors, yet the same retailer's datasheet lists a 60 Hz frame rate in its spec table. The confusion likely stems from an earlier 30 Hz range that became 60 Hz after an update, with the commercial name never catching up. Value used here: 60 Hz, from the detailed spec table rather than the marketing name. A case worth watching, similar in principle to the mix-ups already found at Milwaukee and Hti in this comparison, but here affecting frame rate rather than resolution.
Specifications
Values come from manufacturer documentation unless otherwise
noted in the sources at the bottom of the page. This device has not been physically tested.
Identity
Brand
Fluke
Model
TiS60+
Series
TiS
Release year
not published by the manufacturer
Commercial status
current
EAN code
not published by the manufacturer
Manufacturer reference
FLK-TIS60+
Segment
S4
Sensor and image
Native resolution, width (px)
320
Native resolution, height (px)
240
Native detector pixels
76800
Displayed resolution, width (px)
not applicable
Displayed resolution, height (px)
not applicable
Interpolation method
none
Detector type
uncooled microbolometer
Detector material
not published by the manufacturer
Pixel pitch (µm)
not published by the manufacturer
Spectral band, min (µm)
not published by the manufacturer
Spectral band, max (µm)
not published by the manufacturer
NETD (mK)
45
NETD measurement conditions
not published by the manufacturer
Frame rate (Hz)
60
Optics
Horizontal field of view (°)
34
Vertical field of view (°)
24
Advertised IFOV (mrad)
not published by the manufacturer
Recalculated IFOV (mrad)
1.85
Minimum focus distance (m)
not published by the manufacturer
Focus
automatic
Interchangeable lenses
not published by the manufacturer
Digital zoom (×)
not published by the manufacturer
Macro lens
Availability
no
Reference
not applicable
Working distance (mm)
not applicable
Spot size (µm)
not applicable
Smallest measurable area (µm)
not applicable
Accuracy with macro (°C)
not applicable
Range max with macro (°C)
not applicable
Measurement
Range min (°C)
-20
Range max (°C)
400
Absolute accuracy (°C)
not published by the manufacturer
Relative accuracy (%)
not published by the manufacturer
Emissivity setting
not published by the manufacturer
Reflected temperature correction
not published by the manufacturer
Measurement modes
not published by the manufacturer
Simultaneous cursors
not published by the manufacturer
Full radiometry
not published by the manufacturer
Visible channel
Visible camera (MP)
not published by the manufacturer
Image fusion
not published by the manufacturer
LED light
not published by the manufacturer
Laser pointer
not published by the manufacturer
Ergonomics and ruggedness
Screen (inches)
not published by the manufacturer
Screen resolution
not published by the manufacturer
Touchscreen
not published by the manufacturer
Weight (g)
not published by the manufacturer
Dimensions (mm)
not published by the manufacturer
IP rating
not published by the manufacturer
Drop resistance (m)
not published by the manufacturer
Operating temperature, min (°C)
not published by the manufacturer
Operating temperature, max (°C)
not published by the manufacturer
Power
Power type
system battery
Battery system
Battery Fluke Ti (replaceable)
Battery life (h)
not published by the manufacturer
Charging connector
not published by the manufacturer
Storage and connectivity
Internal memory (GB)
not published by the manufacturer
Memory card
not published by the manufacturer
Wi-Fi
not published by the manufacturer
Bluetooth
not published by the manufacturer
Wired interface
not published by the manufacturer
File formats
not published by the manufacturer
Software
PC software
Fluke Connect Desktop
Free PC software
not published by the manufacturer
Mobile app
Fluke Connect
Report generation
not published by the manufacturer
Cloud service
not published by the manufacturer
Compliance
Calibration certificate provided
not published by the manufacturer
Declared standards
not published by the manufacturer
Warranty (months)
not published by the manufacturer
Support in France
not published by the manufacturer
Observations
A mid-range position within the Fluke lineup. A 320 × 240 sensor, between the already-covered TiS20+ (120 × 90) and TiX501 (640 × 480) in this comparison.
Incomplete documentation on most secondary specs in the sources consulted at this stage; a priority datasheet to flesh out on a future check.