Skip to content
The Thermogram

Fluke · segment S1

Fluke TiS40

€€€

160 × 120 native thermal sensor, NETD 90 mK, 9 Hz.

    Correct or complete this record
    19 200 points measured
    Number of the sensor's measurement points, shown to the catalog's scale. The largest sensor in the database has 327 680 points.
    Published by the manufacturer

    Specifications

    Values come from manufacturer documentation unless otherwise noted in the sources at the bottom of the page. This device has not been physically tested.

    Identity
    BrandFluke
    ModelTiS40
    SeriesTiS Series
    Release year2016
    Commercial statusdiscontinued
    EAN codenot published by the manufacturer
    Manufacturer referenceFLK-TIS40 9HZ
    SegmentS1
    Form factorstandalone handheld camera
    Sensor and image
    Native resolution, width (px)160
    Native resolution, height (px)120
    Native detector pixels19200
    Displayed resolution, width (px)not published by the manufacturer
    Displayed resolution, height (px)not published by the manufacturer
    Interpolation methodsoftware
    Detector typeuncooled microbolometer
    Detector materialnot published by the manufacturer
    Pixel pitch (µm)not published by the manufacturer
    Spectral band, min (µm)7.5
    Spectral band, max (µm)14
    NETD (mK)90
    NETD measurement conditions≤ 0,09 °C / 90 mK @ 30 °C
    Frame rate (Hz)9
    Optics
    Horizontal field of view (°)35.7
    Vertical field of view (°)26.8
    Advertised IFOV (mrad)not published by the manufacturer
    Recalculated IFOV (mrad)3.89
    Minimum focus distance (m)0.15
    Focusfixed
    Interchangeable lensesno
    Digital zoom (×)not published by the manufacturer
    Macro lens
    Availabilityno
    Referencenot published by the manufacturer
    Working distance (mm)not published by the manufacturer
    Spot size (µm)not published by the manufacturer
    Smallest measurable area (µm)not published by the manufacturer
    Accuracy with macro (°C)not published by the manufacturer
    Max range with macro (°C)not published by the manufacturer
    Measurement
    Range min (°C)-20
    Range max (°C)350
    Absolute accuracy (°C)2
    Relative accuracy (%)2
    Emissivity settingcontinuously adjustable
    Reflected temperature correctionyes
    Measurement modes3
    Simultaneous cursors3
    Full radiometryyes
    Visible channel
    Visible camera (MP)yes
    Image fusionoverlay
    LED lightno
    Laser pointerno
    Ergonomics and ruggedness
    Screen (inches)3.5
    Screen resolution320 × 240
    Touchscreenno
    Weight (g)700
    Dimensions (mm)265 × 80 × 120
    IP ratingIP54
    Drop resistance (m)2
    Operating temperature, min (°C)-10
    Operating temperature, max (°C)50
    Power
    Power typeremovable battery
    Battery systemLi-ion
    Battery life (h)4
    Charging connectormicro-USB
    Storage and connectivity
    Internal memory (GB)4000
    Memory cardmicro-SD
    Wi-Fiyes
    Bluetoothno
    Wired interfacemicro-USB
    File formatsBMP ; JPEG ; PNG ; IS2 radiométrique
    Software
    PC softwareFluke Connect / SmartView
    Free PC softwareyes
    Mobile appFluke Connect
    Report generationyes
    Cloud serviceyes
    Compliance
    Calibration certificate providednot published by the manufacturer
    Declared standardsnot published by the manufacturer
    Warranty (months)24
    Support in Francenot published by the manufacturer

    Observations

    • Modèle « point-and-shoot » de la gamme TiS, remplacé depuis par les TiSxx+. Détecteur 160×120 à mise au point fixe, IR-Fusion (AutoBlend + PIP), rapport distance/spot 252:1, écran 3,5" 320×240 non tactile. NETD ≤90 mK correct pour la catégorie. Compatible Fluke Connect pour l'envoi de rapports depuis le terrain. Version standard à 9 Hz ; une variante 60 Hz a existé selon les marchés. À réserver au diagnostic bâtiment/électrique de base : la faible résolution native limite la mesure de petites cibles à distance.

    Sources