Fluke TiS20+

€€€€

120 × 90 native thermal sensor, NETD 60 mK, 9 Hz.

    10 800 points measured
    Number of the sensor's measurement points, shown to the catalog's scale. The largest sensor in the database has 327 680 points.
    Published by the manufacturer

    Specifications

    Values come from manufacturer documentation unless otherwise noted in the sources at the bottom of the page. This device has not been physically tested.

    Identity
    BrandFluke
    ModelTiS20+
    SeriesTiS
    Release yearnot published by the manufacturer
    Commercial statuscurrent
    EAN codenot published by the manufacturer
    Manufacturer referenceFLK-TIS20+ 9HZ
    SegmentS2
    Sensor and image
    Native resolution, width (px)120
    Native resolution, height (px)90
    Native detector pixels10800
    Displayed resolution, width (px)not applicable
    Displayed resolution, height (px)not applicable
    Interpolation methodnone
    Detector typeuncooled microbolometer
    Detector materialnot published by the manufacturer
    Pixel pitch (µm)not published by the manufacturer
    Spectral band, min (µm)not published by the manufacturer
    Spectral band, max (µm)not published by the manufacturer
    NETD (mK)60
    NETD measurement conditionsnot published by the manufacturer
    Frame rate (Hz)9
    Optics
    Horizontal field of view (°)50
    Vertical field of view (°)38
    Advertised IFOV (mrad)7.6
    Recalculated IFOV (mrad)7.27
    Minimum focus distance (m)0.5
    Focusfixed
    Interchangeable lensesno
    Digital zoom (×)not published by the manufacturer
    Macro lens
    Availabilityno
    Referencenot applicable
    Working distance (mm)not applicable
    Spot size (µm)not applicable
    Smallest measurable area (µm)not applicable
    Accuracy with macro (°C)not applicable
    Range max with macro (°C)not applicable
    Measurement
    Range min (°C)-20
    Range max (°C)400
    Absolute accuracy (°C)not published by the manufacturer
    Relative accuracy (%)not published by the manufacturer
    Emissivity settingnot published by the manufacturer
    Reflected temperature correctionnot published by the manufacturer
    Measurement modesnot published by the manufacturer
    Simultaneous cursorsnot published by the manufacturer
    Full radiometryyes
    Visible channel
    Visible camera (MP)not published by the manufacturer
    Image fusionoverlay
    LED lightnot published by the manufacturer
    Laser pointerno
    Ergonomics and ruggedness
    Screen (inches)3.5
    Screen resolution320 × 240
    Touchscreenyes
    Weight (g)not published by the manufacturer
    Dimensions (mm)not published by the manufacturer
    IP ratingIP54
    Drop resistance (m)2
    Operating temperature, min (°C)not published by the manufacturer
    Operating temperature, max (°C)not published by the manufacturer
    Power
    Power typesystem battery
    Battery systemBattery Fluke Ti (replaceable)
    Battery life (h)5
    Charging connectornot published by the manufacturer
    Storage and connectivity
    Internal memory (GB)4
    Memory cardmicroSD
    Wi-Fiyes
    Bluetoothnot published by the manufacturer
    Wired interfaceUSB
    File formatsJPEG and .is2 radiometric
    Software
    PC softwareFluke Connect Desktop
    Free PC softwarenot published by the manufacturer
    Mobile appFluke Connect
    Report generationnot published by the manufacturer
    Cloud servicenot published by the manufacturer
    Compliance
    Calibration certificate providednot published by the manufacturer
    Declared standardsnot published by the manufacturer
    Warranty (months)24
    Support in Francenot published by the manufacturer

    Observations

    • FLUKE ENTRY-LEVEL MODEL, A STARK CONTRAST WITH THE ALREADY-COVERED TiX501 AND Ti401 PRO IN THIS COMPARISON: a 120 × 90 sensor, the smallest of the entire brand, versus 640 × 480 for the flagship models. Same manufacturer, same advertised reliability standard, yet a resolution gap of more than twenty-five times between the cheapest and priciest models in the range.
    • Like the Ti401 PRO, comes in two versions depending on frame rate (9 Hz referenced here), confirming that Fluke systematically splits its ranges along this regulatory criterion rather than treating it as a secondary spec.
    • Full radiometry confirmed, unlike several competing entry-level models in the same price segment that don't document it.
    • Neither measurement accuracy nor NETD conditions are published — a gap also found on the Ti401 PRO from the same brand.