Fluke Ti9

€€€

160 × 120 native thermal sensor, NETD 200 mK, 9 Hz.

    19 200 points measured
    Number of the sensor's measurement points, shown to the catalog's scale. The largest sensor in the database has 327 680 points.
    Published by the manufacturer

    Specifications

    Values come from manufacturer documentation unless otherwise noted in the sources at the bottom of the page. This device has not been physically tested.

    Identity
    BrandFluke
    ModelTi9
    SeriesTi
    Commercial statusdiscontinued
    EAN codenot published by the manufacturer
    Manufacturer referenceTi9
    SegmentS4
    Sensor and image
    Native resolution, width (px)160
    Native resolution, height (px)120
    Native detector pixels19200
    Displayed resolution, width (px)not applicable
    Displayed resolution, height (px)not applicable
    Interpolation methodnone
    Detector typeuncooled microbolometer
    Detector materialnot published by the manufacturer
    Pixel pitch (µm)not published by the manufacturer
    Spectral band, min (µm)7.5
    Spectral band, max (µm)14
    NETD (mK)200
    NETD measurement conditions≤ 200 mK @ 30 °C
    Frame rate (Hz)9
    Optics
    Horizontal field of view (°)23
    Vertical field of view (°)17
    Advertised IFOV (mrad)2.5
    Recalculated IFOV (mrad)2.51
    Minimum focus distance (m)0.15
    Focusfixed
    Interchangeable lensesno
    Digital zoom (×)not published by the manufacturer
    Macro lens
    Availabilityno
    Referencenot applicable
    Working distance (mm)not applicable
    Spot size (µm)not applicable
    Smallest measurable area (µm)not applicable
    Accuracy with macro (°C)not applicable
    Range max with macro (°C)not applicable
    Measurement
    Range min (°C)-20
    Range max (°C)250
    Absolute accuracy (°C)not published by the manufacturer
    Relative accuracy (%)5
    Emissivity settingnot published by the manufacturer
    Reflected temperature correctionnot published by the manufacturer
    Measurement modesnot published by the manufacturer
    Simultaneous cursorsnot published by the manufacturer
    Full radiometryyes
    Visible channel
    Visible camera (MP)not published by the manufacturer
    Image fusionno
    LED lightnot published by the manufacturer
    Laser pointerno
    Ergonomics and ruggedness
    Screen (inches)3.6
    Screen resolution640 × 480
    Touchscreenno
    Weight (g)not published by the manufacturer
    Dimensions (mm)not published by the manufacturer
    IP ratingIP54
    Drop resistance (m)2
    Operating temperature, min (°C)not published by the manufacturer
    Operating temperature, max (°C)not published by the manufacturer
    Power
    Power typesystem battery
    Battery systemBattery Fluke Ti (2h de charge)
    Battery life (h)4
    Charging connectornot published by the manufacturer
    Storage and connectivity
    Internal memory (GB)not applicable
    Memory cardSD
    Wi-Fino
    Bluetoothnot published by the manufacturer
    Wired interfaceUSB
    File formats.is2 radiometric; .bmp non-radiometric
    Software
    PC softwareSmartView
    Free PC softwareyes
    Mobile appnot applicable
    Report generationnot published by the manufacturer
    Cloud servicenot published by the manufacturer
    Compliance
    Calibration certificate providednot published by the manufacturer
    Declared standardsnot published by the manufacturer
    Warranty (months)24
    Support in Francenot published by the manufacturer

    Observations

    • The worst NETD of the entire Fluke brand in this comparison, and one of the worst in the whole catalog. 200 mK, versus 40 to 75 mK for the other already-documented Fluke models (TiS20+, TiS55+, TiS60+, TiS75+, TiX501, Ti401 PRO). The brand's original entry-level model, now discontinued, which shows just how far entry-level sensitivity has come since: the €40 smartphone modules in today's catalog now outperform this original professional Fluke model.
    • Recommended calibration cycle of 2 years, matching its warranty period — a practice Fluke documents explicitly, unlike most other brands in this comparison.