Skip to content
The Thermogram

Fluke · segment S4

Fluke Ti450 PRO

€€€€€

320 × 240 native thermal sensor, NETD 25 mK, 60 Hz.

    Correct or complete this record
    76 800 points measured
    Number of the sensor's measurement points, shown to the catalog's scale. The largest sensor in the database has 327 680 points.
    Published by the manufacturer

    Specifications

    Values come from manufacturer documentation unless otherwise noted in the sources at the bottom of the page. This device has not been physically tested.

    Identity
    BrandFluke
    ModelTi450 PRO
    SeriesTi PRO
    Release yearnot published by the manufacturer
    Commercial statusdiscontinued
    EAN codenot published by the manufacturer
    Manufacturer referencenot published by the manufacturer
    SegmentS4
    Form factorstandalone handheld camera
    Sensor and image
    Native resolution, width (px)320
    Native resolution, height (px)240
    Native detector pixels76800
    Displayed resolution, width (px)640
    Displayed resolution, height (px)480
    Interpolation ratio4
    Interpolation methodoptical micro-scanning
    Detector typeuncooled microbolometer
    Detector materialnot published by the manufacturer
    Pixel pitch (µm)not published by the manufacturer
    Spectral band, min (µm)7.5
    Spectral band, max (µm)14
    NETD (mK)25
    NETD measurement conditions≤ 25 mK @ 30 °C
    Frame rate (Hz)60
    Optics
    Horizontal field of view (°)24
    Vertical field of view (°)17
    Advertised IFOV (mrad)1.31
    Recalculated IFOV (mrad)1.31
    Minimum focus distance (m)0.15
    Focuslaser-assisted autofocus
    Interchangeable lensesyes
    Digital zoom (×)not published by the manufacturer
    Macro lens
    Availabilityoptional
    ReferenceFluke macro lens (compatible)
    Working distance (mm)not published by the manufacturer
    Spot size (µm)not published by the manufacturer
    Smallest measurable area (µm)not published by the manufacturer
    Accuracy with macro (°C)not published by the manufacturer
    Range max with macro (°C)not published by the manufacturer
    Measurement
    Range min (°C)-10
    Range max (°C)1500
    Absolute accuracy (°C)2
    Relative accuracy (%)2
    Emissivity settingcontinuous
    Reflected temperature correctionyes
    Measurement modesnot published by the manufacturer
    Simultaneous cursorsnot published by the manufacturer
    Full radiometrynot published by the manufacturer
    Visible channel
    Visible camera (MP)not published by the manufacturer
    Image fusionoverlay
    LED lightnot published by the manufacturer
    Laser pointeryes
    Ergonomics and ruggedness
    Screen (inches)not published by the manufacturer
    Screen resolutionnot published by the manufacturer
    Touchscreenyes
    Weight (g)1040
    Dimensions (mm)277 × 122 × 167
    IP ratingIP54
    Drop resistance (m)2
    Operating temperature, min (°C)not published by the manufacturer
    Operating temperature, max (°C)not published by the manufacturer
    Power
    Power typeremovable battery
    Battery systemFluke Ti batteries (replaceable)
    Battery life (h)not published by the manufacturer
    Charging connectornot published by the manufacturer
    Storage and connectivity
    Internal memory (GB)not published by the manufacturer
    Memory cardmicroSD
    Wi-Fiyes
    Bluetoothnot published by the manufacturer
    Wired interfaceUSB, HDMI
    File formatsnot published by the manufacturer
    Software
    PC softwareFluke Connect (analysis and reporting)
    Free PC softwarenot published by the manufacturer
    Mobile appFluke Connect
    Report generationnot published by the manufacturer
    Cloud serviceFluke Connect
    Compliance
    Calibration certificate providednot published by the manufacturer
    Declared standardsnot published by the manufacturer
    Warranty (months)24
    Support in Francenot published by the manufacturer

    Observations

    • Discontinued: Fluke lists it as discontinued or reclassified. It is still common on the used market and in remaining stock.
    • SuperResolution: four slightly shifted images are combined to produce 640 × 480. This is software processing from several captures, not a 640 × 480 sensor.
    • 25 mK NETD at 30 °C, very low for a 320 × 240 sensor: this is the device's main argument against cameras of the same resolution.
    • MultiSharp combines several focus positions for an image sharp both near and far; LaserSharp sets focus from the laser rangefinder.
    • Weight, dimensions, drop and IP rating come from the Ti400 PRO sheet, which shares the same housing.
    • Range not calibrated below -10 °C.

    Sources