320 × 240 native thermal sensor,
NETD 45 mK, not published by the manufacturer Hz.
Number of the sensor's measurement points, shown to the catalog's scale.
The largest sensor in the database has 327 680 points.
Published by the manufacturer
Specifications
Values come from manufacturer documentation unless otherwise
noted in the sources at the bottom of the page. This device has not been physically tested.
Identity
Brand
Fluke
Model
Ti32
Series
Ti
Commercial status
discontinued
EAN code
not published by the manufacturer
Manufacturer reference
Ti32
Segment
S5
Sensor and image
Native resolution, width (px)
320
Native resolution, height (px)
240
Native detector pixels
76800
Displayed resolution, width (px)
not applicable
Displayed resolution, height (px)
not applicable
Interpolation method
none
Detector type
uncooled microbolometer
Detector material
not published by the manufacturer
Pixel pitch (µm)
not published by the manufacturer
Spectral band, min (µm)
7.5
Spectral band, max (µm)
14
NETD (mK)
45
NETD measurement conditions
≤ 45 mK
Frame rate (Hz)
not published by the manufacturer
Optics
Horizontal field of view (°)
23
Vertical field of view (°)
17
Advertised IFOV (mrad)
1.25
Recalculated IFOV (mrad)
1.25
Minimum focus distance (m)
0.15
Focus
manual
Interchangeable lenses
yes
Digital zoom (×)
not published by the manufacturer
Macro lens
Availability
no
Reference
not applicable
Working distance (mm)
not applicable
Spot size (µm)
not applicable
Smallest measurable area (µm)
not applicable
Accuracy with macro (°C)
not applicable
Range max with macro (°C)
not applicable
Measurement
Range min (°C)
-20
Range max (°C)
600
Absolute accuracy (°C)
2
Relative accuracy (%)
2
Emissivity setting
continuous
Reflected temperature correction
yes
Measurement modes
not published by the manufacturer
Simultaneous cursors
not published by the manufacturer
Full radiometry
yes
Visible channel
Visible camera (MP)
2
Image fusion
overlay
LED light
not published by the manufacturer
Laser pointer
no
Ergonomics and ruggedness
Screen (inches)
3.7
Screen resolution
640 × 480
Touchscreen
no
Weight (g)
1050
Dimensions (mm)
277 × 122 × 170
IP rating
IP54
Drop resistance (m)
2
Operating temperature, min (°C)
-10
Operating temperature, max (°C)
50
Power
Power type
system battery
Battery system
Battery Fluke Ti (replaceable sur le terrain)
Battery life (h)
not published by the manufacturer
Charging connector
not published by the manufacturer
Storage and connectivity
Internal memory (GB)
not applicable
Memory card
no
Wi-Fi
no
Bluetooth
not published by the manufacturer
Wired interface
USB
File formats
JPEG, JPG, BMP, GIF, PNG, TIF
Software
PC software
SmartView
Free PC software
yes
Mobile app
not applicable
Report generation
not published by the manufacturer
Cloud service
not published by the manufacturer
Compliance
Calibration certificate provided
not published by the manufacturer
Declared standards
IEC 61010-1 ; IEC 61326-1
Warranty (months)
24
Support in France
not published by the manufacturer
Observations
Advertised as Fluke's historic flagship. An IFOV of 1.25 mrad, consistent with recalculating from its 23° field of view and 320 columns, with an optional telephoto lens bringing it down to 0.63 mrad.
IR-Fusion, a patented Fluke technology. Automatic parallax correction between the visible and thermal images, an approach to image fusion different from the simple overlay already documented on most other brands.
1.05 kg, one of the heaviest devices in the entire catalog alongside the already-covered RS PRO 179-9511 (920 g) and Fluke TiS55+.
Voice annotation recorded directly on each image, a feature already seen at testo, Trotec, and Chauvin Arnoux, but here at Fluke as far back as this older model: so the feature isn't new to the industry, contrary to what its presentation at other brands might suggest.
Discontinued model, since replaced by the TiS and TiX ranges.