Editorial detector visualization; the stated native-resolution figure is authoritative.
Published by the manufacturer
Specifications
Values come from manufacturer documentation. This device has not been physically tested.
Identity
Brand
Fluke
Model
TC01A
Series
iSee
Release year
not published by the manufacturer
Commercial status
current
GTIN / EAN
not published by the manufacturer
Manufacturer part number
5518338
Segment
S1
Sensor and image
Native resolution, width (px)
256
Native resolution, height (px)
192
Native detector pixels
49152
Output resolution, width (px)
not applicable
Output resolution, height (px)
not applicable
Upscaling method
none
Detector type
uncooled microbolometer
Detector material
not published by the manufacturer
Pixel pitch (µm)
12
Spectral range, minimum (µm)
8
Spectral range, maximum (µm)
14
NETD (mK)
50
NETD measurement conditions
50 mK (conditions not published)
Frame rate (Hz)
25
Optics
Horizontal field of view (°)
56
Vertical field of view (°)
42
Published IFOV (mrad)
3.81
Recalculated IFOV (mrad)
3.82
Minimum focus distance (m)
0.25
Focus
fixed
Interchangeable lenses
no
Digital zoom (×)
not published by the manufacturer
Macro capability
Availability
no
Reference
not applicable
Working distance (mm)
not applicable
Spot size (µm)
not applicable
Smallest measurable area (µm)
not applicable
Macro accuracy (°C)
not applicable
Maximum macro range (°C)
not applicable
Measurement
Minimum range (°C)
-10
Maximum range (°C)
550
Absolute accuracy (°C)
2
Relative accuracy (%)
2
Emissivity control
continuously adjustable
Reflected-temperature correction
not published by the manufacturer
Measurement modes
not published by the manufacturer
Simultaneous cursors
not published by the manufacturer
Full radiometry
yes
Visible channel
Visible camera (MP)
not applicable
Image fusion
no
LED light
no
Laser pointer or rangefinder
no
Ergonomics and ruggedness
Display (inches)
not applicable
Display resolution
not applicable
Touchscreen
not applicable
Weight (g)
22
Dimensions (mm)
60 × 33.5 × 11.2
IP rating
IP54
Drop resistance (m)
1
Minimum operating temperature (°C)
0
Maximum operating temperature (°C)
40
Power
Power type
external power
Battery system
not applicable
Runtime (h)
not applicable
Charging connector
not applicable
Storage and connectivity
Internal memory (GB)
not applicable
Memory card
not applicable
Wi-Fi
not applicable
Bluetooth
not applicable
Wired interface
USB-C
File formats
radiometric images and video
Software
Desktop software
not published by the manufacturer
Free desktop software
not published by the manufacturer
Mobile app
Fluke iSee (Android / HarmonyOS)
Report generation
yes
Cloud service
not published by the manufacturer
Compliance
Calibration certificate supplied
not published by the manufacturer
Declared standards
IEC 60529 ; IEC 61326-1 ; CISPR 11
Warranty (months)
24
Local service support
yes
Notes
22 G ANDROID / HARMONYOS MODULE: the TC01A is powered by the phone and has no display or battery of its own.
The published range for this variant is -10 to 550°C; the closely related TC01B and TC01C reach -20°C, but that value is not assigned to the TC01A.
Fluke directly publishes a 3.81 mrad IFOV. Recalculation from the 56° field and 256 horizontal pixels gives 3.82 mrad, confirming that the data are internally consistent.