Number of the sensor's measurement points, shown to the catalog's scale.
The largest sensor in the database has 327,680 points.
Published by the manufacturer
Specifications
Values come from manufacturer documentation unless otherwise
noted in the sources at the bottom of the page. This device has not been physically tested.
Identity
Brand
Fluke
Model
PTi120
Series
Pocket
Commercial status
current
EAN code
not published by the manufacturer
Manufacturer reference
FLK-PTI120 9HZ 400C
Segment
S2
Sensor and image
Native resolution, width (px)
120
Native resolution, height (px)
90
Native detector pixels
10800
Displayed resolution, width (px)
120
Displayed resolution, height (px)
90
Interpolation ratio
1.0
Interpolation method
none
Detector type
uncooled microbolometer
Detector material
not published by the manufacturer
Pixel pitch (µm)
not published by the manufacturer
Spectral band, min (µm)
7.5
Spectral band, max (µm)
14
NETD (mK)
60
NETD measurement conditions
not published by the manufacturer
Frame rate (Hz)
9
Optics
Horizontal field of view (°)
not published by the manufacturer
Vertical field of view (°)
not published by the manufacturer
Advertised IFOV (mrad)
7.6
Recalculated IFOV (mrad)
not published by the manufacturer
Minimum focus distance (m)
0.5
Focus
fixed
Interchangeable lenses
no
Digital zoom (×)
not published by the manufacturer
Macro lens
Availability
no
Reference
not applicable
Working distance (mm)
not applicable
Spot size (µm)
not applicable
Smallest measurable area (µm)
not applicable
Accuracy with macro (°C)
not applicable
Range max with macro (°C)
not applicable
Measurement
Range min (°C)
-20
Range max (°C)
400
Absolute accuracy (°C)
2
Relative accuracy (%)
2
Emissivity setting
continuous
Reflected temperature correction
yes
Measurement modes
not published by the manufacturer
Simultaneous cursors
not published by the manufacturer
Full radiometry
yes
Visible channel
Visible camera (MP)
not published by the manufacturer
Image fusion
not published by the manufacturer
LED light
not published by the manufacturer
Laser pointer
no
Ergonomics and ruggedness
Screen (inches)
3.5
Screen resolution
320 × 240
Touchscreen
yes
Weight (g)
233
Dimensions (mm)
89 × 127 × 25
IP rating
IP54
Drop resistance (m)
1
Operating temperature, min (°C)
not published by the manufacturer
Operating temperature, max (°C)
not published by the manufacturer
Power
Power type
built-in battery
Battery system
not applicable
Battery life (h)
2
Charging connector
not published by the manufacturer
Storage and connectivity
Internal memory (GB)
not published by the manufacturer
Memory card
not published by the manufacturer
Wi-Fi
yes
Bluetooth
no
Wired interface
USB
File formats
not published by the manufacturer
Software
PC software
not published by the manufacturer
Free PC software
yes
Mobile app
not published by the manufacturer
Report generation
yes
Cloud service
Fluke Connect
Compliance
Calibration certificate provided
not published by the manufacturer
Declared standards
not published by the manufacturer
Warranty (months)
not published by the manufacturer
Support in France
not published by the manufacturer
Observations
The most compact pocket format in this Fluke comparison (233 g). Field of view isn't published by Fluke; only the distance-to-spot ratio (130:1, IFOV 7.6 mrad) is documented.
Two versions exist depending on temperature range (-20 to 150°C or -20 to 400°C): it's the 400°C version described here.