Skip to content
The Thermogram

FLIR · segment S3

FLIR TG267

€€

160 × 120 native thermal sensor, NETD 70 mK, 9 Hz.

    19 200 points measured
    Number of the sensor's measurement points, shown to the catalog's scale. The largest sensor in the database has 327 680 points.
    Published by the manufacturer

    Specifications

    Values come from manufacturer documentation unless otherwise noted in the sources at the bottom of the page. This device has not been physically tested.

    Identity
    BrandFLIR
    ModelTG267
    SeriesTG
    Release year2019
    Commercial statusdiscontinued
    EAN codenot published by the manufacturer
    Manufacturer reference87502-0202
    SegmentS3
    Sensor and image
    Native resolution, width (px)160
    Native resolution, height (px)120
    Native detector pixels19200
    Displayed resolution, width (px)not applicable
    Displayed resolution, height (px)not applicable
    Interpolation methodnone
    Detector typeuncooled microbolometer
    Detector materialnot published by the manufacturer
    Pixel pitch (µm)not published by the manufacturer
    Spectral band, min (µm)not published by the manufacturer
    Spectral band, max (µm)not published by the manufacturer
    NETD (mK)70
    NETD measurement conditionsnot published by the manufacturer
    Frame rate (Hz)9
    Optics
    Horizontal field of view (°)57
    Vertical field of view (°)44
    Advertised IFOV (mrad)not published by the manufacturer
    Recalculated IFOV (mrad)6.22
    Minimum focus distance (m)not published by the manufacturer
    Focusfixed
    Interchangeable lensesno
    Digital zoom (×)not published by the manufacturer
    Macro lens
    Availabilityno
    Referencenot applicable
    Working distance (mm)not applicable
    Spot size (µm)not applicable
    Smallest measurable area (µm)not applicable
    Accuracy with macro (°C)not applicable
    Range max with macro (°C)not applicable
    Measurement
    Range min (°C)-25
    Range max (°C)380
    Absolute accuracy (°C)not published by the manufacturer
    Relative accuracy (%)not published by the manufacturer
    Emissivity settingnot published by the manufacturer
    Reflected temperature correctionnot published by the manufacturer
    Measurement modes1
    Simultaneous cursorsnot published by the manufacturer
    Full radiometrynot published by the manufacturer
    Visible channel
    Visible camera (MP)not published by the manufacturer
    Image fusionoverlay
    LED lightyes
    Laser pointeryes
    Ergonomics and ruggedness
    Screen (inches)2.4
    Screen resolution320 × 240
    Touchscreenno
    Weight (g)not published by the manufacturer
    Dimensions (mm)not published by the manufacturer
    IP ratingIP54
    Drop resistance (m)2
    Operating temperature, min (°C)not published by the manufacturer
    Operating temperature, max (°C)not published by the manufacturer
    Power
    Power typebuilt-in battery
    Battery systemnot applicable
    Battery life (h)5
    Charging connectorUSB-C
    Storage and connectivity
    Internal memory (GB)4
    Memory cardno
    Wi-Fino
    Bluetoothyes
    Wired interfaceUSB-C
    File formatsnot published by the manufacturer
    Software
    PC softwareFLIR Tools
    Free PC softwareyes
    Mobile appFLIR Tools Mobile
    Report generationnot published by the manufacturer
    Cloud servicenot published by the manufacturer
    Compliance
    Calibration certificate providednot published by the manufacturer
    Declared standardsnot published by the manufacturer
    Warranty (months)not published by the manufacturer
    Support in Francenot published by the manufacturer

    Observations

    • Model DISCONTINUED by FLIR, replaced by the TG268. Still widely available from French retailers, often with no mention of its discontinued status.
    • A 57° field of view for 160 pixels. The recalculated spatial resolution is the second worst in the comparison, just behind the TG165-X. An imaging thermometer is meant to locate an anomaly, not to detail it.
    • Type K thermocouple included, to complement the non-contact reading with a contact measurement. It's the only model in this comparison to offer it.
    • Neither measurement accuracy, nor NETD conditions, nor spectral band are published.