Number of the sensor's measurement points, shown to the catalog's scale.
The largest sensor in the database has 327 680 points.
Published by the manufacturer
Calculation convention. The comparator uses a 5.89 mrad mean angular pitch (54°/160). FLIR publishes 6.3 mrad; an optical projection at the image centre gives about 6.37 mrad. The figures use different conventions and do not establish a manufacturer error.
Specifications
Values come from manufacturer documentation unless otherwise
noted in the sources at the bottom of the page. This device has not been physically tested.
Identity
Brand
FLIR
Model
C5
Series
Cx
Release year
2020
Commercial status
current
EAN code
not published by the manufacturer
Manufacturer reference
89401-0202
Segment
S2
Form factor
standalone handheld camera
Sensor and image
Native resolution, width (px)
160
Native resolution, height (px)
120
Native detector pixels
19200
Displayed resolution, width (px)
not applicable
Displayed resolution, height (px)
not applicable
Interpolation method
none
Detector type
uncooled microbolometer
Detector material
not published by the manufacturer
Pixel pitch (µm)
12
Spectral band, min (µm)
8
Spectral band, max (µm)
14
NETD (mK)
70
NETD measurement conditions
not published by the manufacturer
Frame rate (Hz)
8.7
Optics
Horizontal field of view (°)
54
Vertical field of view (°)
42
Advertised IFOV (mrad)
6.3
Recalculated IFOV (mrad)
5.89
Minimum focus distance (m)
0.1
Focus
fixed
Interchangeable lenses
no
Digital zoom (×)
4
Macro lens
Availability
no
Reference
not applicable
Working distance (mm)
not applicable
Spot size (µm)
not applicable
Smallest measurable area (µm)
not applicable
Accuracy with macro (°C)
not applicable
Range max with macro (°C)
not applicable
Measurement
Range min (°C)
-20
Range max (°C)
400
Absolute accuracy (°C)
3
Relative accuracy (%)
3
Emissivity setting
custom value
Reflected temperature correction
yes
Measurement modes
not published by the manufacturer
Simultaneous cursors
not published by the manufacturer
Full radiometry
yes
Visible channel
Visible camera (MP)
5
Image fusion
overlay
LED light
yes
Laser pointer
no
Ergonomics and ruggedness
Screen (inches)
3.5
Screen resolution
not published by the manufacturer
Touchscreen
yes
Weight (g)
not published by the manufacturer
Dimensions (mm)
not published by the manufacturer
IP rating
IP54
Drop resistance (m)
2
Operating temperature, min (°C)
-10
Operating temperature, max (°C)
50
Power
Power type
built-in battery
Battery system
not applicable
Battery life (h)
4
Charging connector
USB-C
Storage and connectivity
Internal memory (GB)
not published by the manufacturer
Memory card
no
Wi-Fi
yes
Bluetooth
yes
Wired interface
USB
File formats
Radiometric JPEG (14-bit measurement data)
Software
PC software
FLIR Thermal Studio
Free PC software
yes
Mobile app
FLIR Ignite
Report generation
yes
Cloud service
yes
Compliance
Calibration certificate provided
not published by the manufacturer
Declared standards
not published by the manufacturer
Warranty (months)
not published by the manufacturer
Support in France
not published by the manufacturer
Observations
Degraded accuracy. ±3°C or ±3%, versus ±2°C across the entire HIKMICRO B series sold for less. This is the worst accuracy among the standalone devices in this comparison.
Minimum focus distance of 0.10 m in thermal mode, but 0.30 m as soon as MSX mode is enabled: FLIR's flagship feature reduces the useful working distance.
Explicit export notice from distributors. Sale and export banned to China, Hong Kong, Russia, and Venezuela.
Thermal Studio Starter is free; the Standard and Pro versions are subscription-based.