Extech IRC130

€€

80 × 60 native thermal sensor, NETD 70 mK, not published by the manufacturer Hz.

    4 800 points measured
    Number of the sensor's measurement points, shown to the catalog's scale. The largest sensor in the database has 327 680 points.
    Published by the manufacturer

    Specifications

    Values come from manufacturer documentation unless otherwise noted in the sources at the bottom of the page. This device has not been physically tested.

    Identity
    BrandExtech
    ModelIRC130
    SeriesIRC
    Commercial statuscurrent
    EAN codenot published by the manufacturer
    Manufacturer referenceIRC130
    SegmentS3
    Sensor and image
    Native resolution, width (px)80
    Native resolution, height (px)60
    Native detector pixels4800
    Displayed resolution, width (px)not applicable
    Displayed resolution, height (px)not applicable
    Interpolation methodnone
    Detector typeuncooled microbolometer
    Detector materialnot published by the manufacturer
    Pixel pitch (µm)not published by the manufacturer
    Spectral band, min (µm)not published by the manufacturer
    Spectral band, max (µm)not published by the manufacturer
    NETD (mK)70
    NETD measurement conditionsnot published by the manufacturer
    Frame rate (Hz)not published by the manufacturer
    Optics
    Horizontal field of view (°)51
    Vertical field of view (°)66
    Advertised IFOV (mrad)not published by the manufacturer
    Recalculated IFOV (mrad)11.13
    Minimum focus distance (m)not published by the manufacturer
    Focusautomatic
    Interchangeable lensesno
    Digital zoom (×)not published by the manufacturer
    Macro lens
    Availabilityno
    Referencenot applicable
    Working distance (mm)not applicable
    Spot size (µm)not applicable
    Smallest measurable area (µm)not applicable
    Accuracy with macro (°C)not applicable
    Range max with macro (°C)not applicable
    Measurement
    Range min (°C)-25
    Range max (°C)650
    Absolute accuracy (°C)1
    Relative accuracy (%)1
    Emissivity settingcontinuous
    Reflected temperature correctionnot published by the manufacturer
    Measurement modesnot published by the manufacturer
    Simultaneous cursorsnot published by the manufacturer
    Full radiometrynot published by the manufacturer
    Visible channel
    Visible camera (MP)not published by the manufacturer
    Image fusionno
    LED lightnot published by the manufacturer
    Laser pointerno
    Ergonomics and ruggedness
    Screen (inches)2.4
    Screen resolution240 × 320
    Touchscreenno
    Weight (g)823
    Dimensions (mm)210 × 64 × 81
    IP ratingIP54
    Drop resistance (m)2
    Operating temperature, min (°C)not published by the manufacturer
    Operating temperature, max (°C)not published by the manufacturer
    Power
    Power typebuilt-in battery
    Battery systemLithium 3,7V
    Battery life (h)not published by the manufacturer
    Charging connectornot published by the manufacturer
    Storage and connectivity
    Internal memory (GB)not applicable
    Memory cardno
    Wi-Fino
    Bluetoothnot published by the manufacturer
    Wired interfaceUSB
    File formatsJPEG
    Software
    PC softwarenot published by the manufacturer
    Free PC softwarenot published by the manufacturer
    Mobile appnot applicable
    Cloud servicenot published by the manufacturer
    Compliance
    Calibration certificate providednot published by the manufacturer
    Declared standardsnot published by the manufacturer
    Warranty (months)not published by the manufacturer
    Support in Francenot published by the manufacturer

    Observations

    • Geometrically suspect field of view, a pattern already seen on the FLIR TG165-X. The datasheet lists 51° horizontal and 66° vertical, i.e. a field taller than it is wide on an 80 × 60 sensor that is nonetheless in landscape format. As with the TG165-X, the two values are likely swapped in the distributor's documentation.
    • The lowest resolution in the catalog after the Chauvin Arnoux C.A 1950 and the PerfectPrime IR0280. 80 × 60, i.e. 4,800 measurement points, identical to the FLIR ONE Pro LT already covered.
    • ADVERTISED ACCURACY OF ±1°C, BETTER THAN ALMOST THE ENTIRE CATALOG despite this very low resolution: the accuracy of a single-point reading and the spatial resolution of the image are two independent qualities, and this device illustrates that clearly.
    • Extech belongs to the same group (Teledyne FLIR) as the FLIR brand, already extensively covered in this comparison, though the two ranges do not overlap on the models documented here.